Artiklar 0
5337D
 
 

5337D

 

2-wire transmitter with HART protocol

 

  • RTD, TC, Ohm, and bipolar mV input
  • 2 analog inputs and 5 device variables with status available
  • HART protocol revision selectable from HART 5 or HART 7
  • Hardware assessed for use in SIL applications
  • Mounting in hazardous gas and dust area
  1. Overview +

  2. Technical details +

  3. Accessories +


Application

  • Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100.
  • HART communication and 4...20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors.
  • Conversion of linear resistance to a standard analog current signal, e.g from valves or Ohmic level sensors.
  • Amplification of bipolar mV signals to standard 4...20 mA current signals.
  • Up to 63 transmitters (HART 7) can be connected in a multidrop communication setup.

Technical characteristics

  • HART protocol revision can be changed by user configuration to either HART 5 or HART 7 protocol.
  • The HART 7 protocol offers:
    ∙ Long Tag numbers of up to 32 characters.
    ∙ Enhanced Burst Mode and Event notification with time stamping.
    ∙ Device variable and status mapping to any dynamic variable PV, SV, TV or QV.
    ∙ Process signal trend measurement with logs and summary data.
    ∙ Automatic event notification with time stamps.
    ∙ Command aggregation for higher communication efficiency.
  • 5337D is designed according to strict safety requirements and is therefore suitable for applications in SIL installations.
  • Continuous check of vital stored data.
  • Meeting the NAMUR NE 21 recommendations, the 5337 HART transmitter ensures top measurement performance in harsh EMC environments. Additionally, the 5337D meets NAMUR NE43 and NE89 recommendations.

Mounting / installation

  • For DIN form B sensor head mounting.
  • Configuration via standard HART communication interfaces or by PR 5909 Loop Link.

Environmental Conditions

  • Operating temperature

    -40°C to +85°C

  • Calibration temperature

    20...28°C

  • Relative humidity

    < 95% RH (non-cond.)

  • Protection degree (encl./terminal)

    IP68 / IP00

Mechanical specifications

  • Dimensions

    Ø 44 x 20.2 mm

  • Weight approx.

    50 g

  • Wire size

    1 x 1.5 mm2 stranded wire

  • Screw terminal torque

    0.4 Nm

  • Vibration

    IEC 60068-2-6

  • 2...25 Hz

    ±1.6 mm

  • 25...100 Hz

    ±4 g

Common specifications

  • Supply

  • Supply voltage

    8.0...30 VDC

  • Isolation voltage

  • Isolation voltage, test / working

    1.5 kVAC / 50 VAC

  • Response time

  • Response time (programmable)

    1...60 s

  • Voltage drop

    8.0 VDC

  • Programming

    Loop Link & HART

  • Signal / noise ratio

    > 60 dB

  • Accuracy

    Better than 0.05% of selected range

  • Signal dynamics, input

    22 bit

  • Signal dynamics, output

    16 bit

  • EMC immunity influence

    < ±0.1% of span

  • Extended EMC immunity: NAMUR NE21, A criterion, burst

    < ±1% of span

Input specifications

  • Common input specifications

  • Max. offset

    50% of selected max. value

  • RTD input

  • RTD type

    Pt50/100/200/500/1000; Ni50/100/120/1000

  • Cable resistance per wire

    5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy)

  • Sensor current

    Nom. 0.2 mA

  • TC input

  • Thermocouple type

    B, E, J, K, L, N, R, S, T, U, W3, W5, LR

  • Cold junction compensation (CJC)

    Constant, internal or external via a Pt100 or Ni100 sensor

  • Voltage input

  • Measurement range

    -800...+800 mV

  • Min. measurement range (span)

    2.5 mV

  • Input resistance

    10 MΩ

Output specifications

  • Current output

  • Signal range

    4…20 mA

  • Min. signal range

    16 mA

  • Load (@ current output)

    ≤ (Vsupply - 8) / 0.023 [Ω]

  • Sensor error indication

    Programmable 3.5…23 mA

  • NAMUR NE43 Upscale/Downscale

    23 mA / 3.5 mA

  • Common output specifications

  • Updating time

    440 ms

  • HART protocol revisions

    HART 7 and HART 5

Observed authority requirements

  • EMC

    2014/30/EU

  • EAC

    TR-CU 020/2011

Approvals

  • ATEX 2014/34/EU

    KEMA 03ATEX1537

  • IECEx

    KEM 10.0083X

  • FM

    FM17US0013X

  • CSA

    1125003

  • INMETRO

    DEKRA 18.0002X

  • EAC Ex TR-CU 012/2011

    RU C-DK.GB08.V.00410

  • DNV-GL Marine

    Stand. f. Certific. No. 2.4

  • SIL

    Hardware assessed for use in SIL applications

Din förfrågan har skickats. - 0 Artiklar på din lista
Produktbeskrivning Antal
Vänligen ange artikelnummer och ev. variant (se datablad för mer info) – eller ange “Artikelnummer okänt”
Er kontaktinformation
Bläddra vidare
Inga produkter har lagts till i listan…
Du har inga produkter på listan…

När du ser dig omkring bland produkterna på vår hemsida har ni möjlighet att lägga till produkter i en lista och skicka denna lista till oss och därmed begära en offert. Du kan lägga till produkter i listan genom att klicka på ”Få en enkel offert”- knappen på de enskilda produktsidorna.

När du har skickat listan kommer vi att återkoppla till dig så snart som möjligt.

Om du inte skickar listan kommer den att vara synlig på webbplatsen i 7 dagar (vi kommer att använda oss av ”cookies” på din dator eller surfplatta)

Vi hoppas att ni finner denna funktion användbar. Gå till produktsidorna för att lägga till produkter i din lista.
Tack för din förfrågan.
Vi kommer att återkoppla till dig via telefon eller e-mail så snart som möjligt.